◆ Strong and durable: Fully enclosed design, the highest IP68 protection level?
◆ Straight line measurement Absolute output, no need to return to zero?
◆ Easy to use: Standard signal output, maintenance free?
◆Never wear: Continuous non-contact measurement?
◆ Full range adjustable: 100% adjustable zero and full range?
◆ High resolution: The highest resolution is 0.5um
Input
Measurement data location
Measurement range: 50mm-7650mm
?
Output
Voltage:0~10Vdc,10~0Vdc,0~5Vdc,5~0Vdc
(controller minimum load:?>5k Ohms)
Electric current:?4~20mA,20~4mA,0~20mA,20~0mA
(minimum / heavy load 0 / 500 Ohms)
?
Accuracy
Resolution 16 bit D / A, up to 0.5um??????
Nonlinearity < 0.02% of full scale (minimum 100um)
Repeatability < 0.002% of full scale or the same as resolution
Update time 0.5ms (range ≤ 1200mm)
1.0ms (range ≤ 2400mm)
2.0ms (range ≤ 4800mm)
5.0ms (range ≤ 7650mm)
?
Working conditions
Magnetic ring speed: arbitrary
Working temperature?:- 40?~?85?℃
Humidity / dew point humidity?:90%, no condensation
Temperature coefficient<30ppm /?℃
Protection grade:IP65 RP aluminum forming outer pipe
IP67 RH pressure outer tube???????
IP68 RH pressure resistant outer pipe (waterproof type)
?
?
?
Structure and materials
RP series:?????Electronic warehouse:?Aluminum alloy profiles?????????????????
Measuring rod:?Aluminum alloy???????
Magnet:?Slider magnet or floating magnet????
RH series:?????Electronic warehouse:Aluminium alloy profile????????????????????
Measuring rod:stainless steel 304 or 316L????
Magnetic ring:Standard magnetic ring or open magnetic ring???????
Outer pipe pressure40MPa (continuous)
60MPa (peak value)
?
Install
Installation direction:arbitrary direction
Thread form:?metric m18 × 1.5?,M20 × 1.5
British system 3 / 4 "- 16UNF-3A
?
Electrical connection
Outlet type:?waterproof connector or aviation plug
Input voltage:?24 VDC (- 15 ~ + 20%)
polarity protection Maximum?:- 30VDC
Overpressure protection:?Maximum36VDC
Working current?<70mA (varies with measuring range)