Product Introduction
GT series split-type LVDT displacement sensor has excellent performance, the sensor is powered by 12-24VDC,
?is equipped with fisheye head, optional universal joint slider, and the electronic circuit is sealed in a 304 stainless?
steel metal tube, which can be stable for a long time in harsh environments such as humidity and dust Work,
?the output signal is a standard 0-5V or 4-20MA output that can be used by a computer or PLC, or RS485 digital signal
Power supply: 12-24V
Working current: voltage output type supply current: ≤12MA
?????????? Two-wire current output type, power supply current 4-20MA
Displacement range: GT25: 0-5mm; GT50: 0-10mm; GT125: 0-25mm;?
GT250: 0-50mm; GT500: 0-100mm; GT1250: 0-250mm; GT2500: 0-500mm;
?
Output signal: 0-5V, 0-10V, 40-20Ma, RS485 digital signal
Linearity error: analog signal output: ±0.25%FS, ±0.5%FS, etc. optional
Digital signal output: ±0.1%FS, ±0.25%FS, etc. optional
Weight error≤5um
Resolution ≤0.1um
Dynamic characteristics: 200HZ
Measuring force: 80g
Working temperature:-25 ℃ to + 85 ℃
Impact resistance: 250g/11ms
Vibration allowed: 10g/2KHZ
Temperature coefficient: zero point≤0.01%/ ℃
Sensitivity ≤0.025%/ ℃
Application:
Hydraulic cylinder positioning, cement industry, bridge deck displacement detection,?
valve position detection and control, machine tool and tool positioning,?
subway tunnel engineering protection, etc.